1.DataCenters
2.Local Area Networks 3.High-Density Applications 4.Interconnects
3.Cross-connects
Features
1.Uniboot with a Single Housing 2.Unique Push-Pull Design and Function 3.Interchangeable polarity
4.Low insertion loss and added loss. 5.Height of attenuation.
6.High back loss, small volume, lightweight.
7.End-face geometry and quality superior than IEC and Telcordia standards. 8.LSZH, OFNP, OFNR cablejacket.
9.Mechanical performance: IEC 61754-20 standard. 10.RoHS and REACH materials compliant.
Connector Types
Type |
Reference |
Note |
|
LC |
IEC 61754-20 |
Single mode |
UPC: Blue connectors , White boots |
Multimode |
UPC: Grey or Aqua Connectors , White boots |
Patch cord versions
Jumper tolerance requirement |
|
Overall length (L)(M) |
length of tolerance(CM) |
0<L≤20 |
+10/-0 |
20<L≤40 |
+15/-0 |
L>40 |
+0.5%L/-0 |
Cable Structure
Cable Parameters
Fiber account |
OD(mm) |
NominalWeight (kg/km) |
Max.tensile Strength(N) |
Max.Crush Resistance (N/100mm) |
Min.Bending Radius(mm) |
|||
Short-term |
Long-term |
Short-term |
Long-term |
Dynamic |
Static |
|||
2 |
3.0±0.15 |
7.5 |
150 |
80 |
500 |
150 |
20D |
10D |
Optical Characteristics
Item |
Parameter |
Reference |
|
Single mode |
Multimode |
||
Insertion loss |
Typical value≤0.15dB ; Maximum≤0.30 |
Typical value≤0.15dB ; Maximum≤0.30 |
IEC 61300-3-34 |
Return loss |
≥50dB (UPC) |
≥30dB (UPC) |
IEC 61300-3-6 |
End-Face Geometry
Item |
UPC (Ref: IEC 61755-3-1) |
APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) |
7 to 25 |
5 to 12 |
Fiber height (nm) |
-100 to 100 |
-100 to 100 |
Apex offset (μm) |
0 to 50 |
0 to 50 |
APC angle (°) |
/ |
8° ±0.2° |
Key error (°) |
/ |
0.2° max |
End-Face Qualty (SM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 25 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
25 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
End-Face Qualty (MM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 65 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
65 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
Mechanical Characteristics
Test |
Conditions |
Reference |
Endurance |
500 matings |
IEC 61300-2-2 |
Vibration |
Frequency: 10 to 55Hz, Amplitude: 0.75mm |
IEC 61300-2-1 |
Cable retention |
100N (patch cable); 5N (pigtail) |
IEC 61300-2-4 |
Strength of coupling mechanism |
80N for 2 to 3mm cable |
IEC 61300-2-6 |
Cable torsion |
15N for 2 to 3mm cable |
IEC 61300-2-5 |
Fall |
10 drops, 1m drop height |
IEC 61300-2-12 |
Static lateral load |
1N for 1h (patch cable); 0.2N for 5min (pigtail) |
IEC 61300-2-42 |
Cold |
-25°C, 96h duration |
IEC 61300-2-17 |
Dry heat |
+70°C, 96h duration |
IEC 61300-2-18 |
Change of temperature |
-25°C to +70°C, 12 cycles |
IEC 61300-2-22 |
Humidity |
+40°C at 93%, 96h duration |
IEC 61300-2-19 |